Technical specifications
Mold clamp lines
Lines |
HB0101
|
HB0161
|
HB0251
|
HB0401
|
HB0631
|
HB1001
|
HB1601
|
||
Die clamping capacity | (kN) | 9.8 | 15.7 | 24.5 | 39.2 | 61.7 | 98 | 157 | |
Strength | Pressure | 0. 39MPa | 9.8 | 15.7 | 24.5 | 39.2 | 61.7 | 98 | 157 |
(kN) | Application capacity | OMPa | 2.9 | 5.9 | 8.8 | 13.7 | 20.6 | 30.8 | 50.3 |
Force clamp (kN) | Pressure | 0. 49MPa | 7.8 | 13.7 | 20.6 | 32.3 | 50 | 77.4 | 127 |
Pressure | 0.39MPa | 6.9 | 11.8 | 17.6 | 27.4 | 43.1 | 66 | 108 | |
Pressure | OMPa | 2 | 3.9 | 4.9 | 7.8 | 11.8 | 17.7 | 28.9 | |
Maximum cycle | (mm) | 3 | 3 | 32 | 3.6 | 4 | 4.5 | 5 | |
Clamping cycle | (mm) | 1 | 1 | 1 | 1.1 | 1.2 | 1.2 | ||
Reserve cycle | 2 | 2 | 2.2 | 2.5 | 2.8 | 33 | 3.8 | ||
Cylinder volume | Mold clamping face | 56 | 94 | 144 | 259 | 444 | 773 | 1334 | |
(cm3) | Mold release face | 52 | 88 | 135 | 244 | 416 | 729 | 1262 | |
Pressure supply | Recommended pressure | 0.49 | |||||||
(MPa) | Minimum pressure | 0.39 | |||||||
Operating temperature | Below 70°C (above 70°C, please contact us) | ||||||||
Operating frequency | Less than 20 times/day (or you can contact us if there is any change) |
Machine details
Dimensions
Line | E | F | G | J | KA | KB | L | M (h) | N | P | UA | VA | VB | X | Y | Z | MIN.a | MIN.c | MIN.h | MAx.h |
HB0101 | 69 | 50 | 16 | 14 | 65 | – | 148.5 | 27 (36) -47 (15) | 2.5 | 7 | 27.5 | 60 | 10.5 | – | Rc1/8 | – | 10 | 6.5 | 15±0.3 | 35±0.3 |
HB0161 | 77 | 60 | 19 | 16 | 74 | – | 162 | 30 (40) -55 (15) | 2.5 | 7.5 | 26.5 | 64 | 11 | – | Rc1/8 | – | 12 | 8 | 15±0.3 | 40±0.3 |
HB0251 | 87.5 | 72 | 25 | 17 | 87 | – | 181.5 | 40.5 (40) -60.5 (20) | 2.5 | 8.7 | 30.5 | 70 | 11 | – | Rc1/8 | – | 14 | 9.5 | 20±0.3 | 40±0.3 |
HB0401 | 106.5 | 90 | 30 | 20 | 101.5 | – | 201 | 53.5 (45) -78.5 (20) | 2.5 | 10 | 36 | 74.5 | 11.5 | – | Rc1/8 | – | 18 | 12 | 20±0.3 | 45±0.3 |
HB0631 | 131 | 110 | 36 | 22 | 121.5 | – | 236 | 65 (20) -85 (30) | 2.5 | 11 | 51 | 89 | 11.5 | M8 | Rc1/8 | – | 22 | 14 | 30±0.3 | 50±0.3 |
HB1001 | 154 | 135 | 48 | 26 | 143 | 60 | 266.5 | 84 (60) -109 (35) | 3.5 | 13 | 112.5 | 106.5 | 8.5 | M8 | Rc1/8 | – | 24 | 16.5 | 35±0.3 | 60±0.3 |
HB1601 | 186 | 160 | 55 | 30 | 179.5 | 75 | 331.5 | 106 (70) -136 (40) | 3.5 | 17 | 134 | 128 | 12 | M10 | Rc1/4 | 6 | 28 | 20 | 40±0.3 | 70±0.3 |
Characteristics
- The power source is standard compressed air, so users do not need to worry about oil leakage contaminating the clamping machine and affecting the surrounding environment. Therefore, users do not need to worry about oil storage operation or the risk of fire or explosion.
- All circuits use air pressure pipes, making operation and use easier.
- Even when removing the maintenance pipe, there is no oil leakage, making maintenance and cleaning easier.
- Both mold clamps KOSMEK GWA and KOSMEK HB mold clamps both have the same mounting distance between holes, making the two devices compatible with each other.
- Compared to oil pressure mold changing, this HB mold clamp has lower operating pressure, ensuring higher durability at high temperatures.
- The price of HB mold clamp is lower than oil pressure mold clamp, especially for long-term use.
Reviews
There are no reviews yet.